Correct Use Of Electromagnetic Flowmeter
Dec 16, 2021
The correct method of using electromagnetic flowmeter mainly has the following aspects, let's learn together with you. The following twelve items are the most critical in the process of use:
1. It is necessary to keep the cable joints clean and dry, waterproof, moisture-proof, and heat-preserving during heavy snow in extreme weather in the north. The flowmeter and each cable head cover must be screwed on in time after each use.
2. It is forbidden to connect the electromagnetic flowmeter when the pipeline flow is passing, so as to avoid the sharp hard objects in the circulating fluid from scouring and damaging the tetrafluoroethylene lining of the flowmeter and affecting the measurement accuracy.
3. The electromagnetic flowmeter converter cannot be used interchangeably.
4. Ensure that the inner lining of the electromagnetic flowmeter cannot be scratched or punctured by hard objects, which damages its smoothness.
5. After each construction and use, the inner lining of the electromagnetic flowmeter and the variable diameter short-circuit lining must be cleaned in time (use a water gun and a soft cloth to clean the lining). It is strictly forbidden for the inner lining of the flowmeter to contact various oils to pollute the measuring electrode and damage the insulating inner lining.
6. If there is a flow jump at the moment when the pump is turned on for the slurry, the accumulated liquid volume should be "cleared" in time to eliminate the measurement error caused by the signal jump.
7. The electromagnetic flowmeter transmitter (with display device) must be kept clean and must be placed indoors for use, waterproof, moisture-proof, vibration-proof and collision-proof. Keep all cables clean.
8. The 220 volt AC cable head and socket of the electromagnetic flowmeter must not be exposed to moisture or water; do not use wet hands to connect or unplug the wire when using it to prevent the risk of electric shock.
9. After each slurry replacement measurement, fill in the construction date, construction well number, design slurry replacement volume, and flowmeter cumulative data on the flowmeter operation record form.
10. The insulating material of the inner wall of the electromagnetic flowmeter must not be in contact with oily substances, acids, and alkaline substances, so as to avoid the deterioration of the flowmeter's performance and damage to the waste due to the aging of the insulating material.
11. When the flowmeter is installed, disassembled, transported, and stored, it is strictly prohibited to throw the ground from the vehicle or fall to the ground, to prevent the internal precision coil from being deformed or broken due to strong vibration, and damaging the flowmeter.
12. Strictly implement the inspection system for equipment leaving and returning to the site. The flowmeter must be energized to check the working status before and after each use: before departure, it must be energized for inspection, and after returning to the base for cleaning and maintenance, it must be energized to check the working status and make a good inspection record.